Sullair

    • DMD Dryer
      Reset Service
      Remove plastic cover above controller. Find magnetic reed switch on top of controller. Place magnet near switch to reset service alarm.

    • DTS Dryer
      Service Mode
      User: NORTEC Password: 1234

    • Dryer
      Default
      10

    • EC
      Customer
      0607

      User Manual

    • ESD Dryer
      Maintenance
      2013 or older, a jumper wire is required between terminals #1 and #27. Then press and hold the "P" button for 5 seconds. Then enter 10 for the security code, enter to save. Once filter change is selected, press and hold the up & down arrow keys simultaneously for 15 seconds to reset. Post 2013, a jumper wire is not required. However,the security code is the same, "10". Once maintenance is selected, it will ask for another code. Which is "1071". Press and hold the up and down arrow keys simultaneously for 10 seconds to reset.

    • Microvisor 2-v
    • SRL Dryer
    • ST
      Customer
      0607

      Factory
      1008

      User Manual

    • STS
      Technician
      tech

      Modbus Specification

      Technician User Manual

      User Manual

    • Supervisor
      Factory Setup
      If a number appears you must take this number, multiply by 2 and then add 3. For example, if 22 shows then (22 * 2) + 3 = 47.

      User Manual

    • Supervisor II
      Calibrate Sensors
      Logo -> Up -> DSP -> Down -> PRG

      Factory Setup
      Press E-Stop. Press logo button then PGM. If a number appears you must take this number, multiply by 2 and then add 3. For example, if 22 shows then (22 * 2) + 3 = 47. Use logo key to go up by 10 and up arrow to go up by 1. Down arrow goes down by 1. When at the correct password press PGM.

      Sequencing Manual

      User Manual

    • WS
      Modbus Specification

      User Manual